Voted Best Answer

Feb 21, 2023 - 11:33 AM
Type |
Range |
Type |
Range |
Number of Channels |
4 |
Sample Mode |
Normal |
Bandwidth |
100MHz |
Protocol Decoding |
CAN, LIN |
Rise Time |
≤3.5ns (typical) |
Trigger Type |
Edge, Pulse Width |
Real-time sampling rate (Max) |
1Gsa/s(single channel); 500MS/s(dual channel); 250MS/s(four channels) |
Trigger Mode |
Normal, Auto, Single Sequence |
Input Impedance |
1MΩ±1.5% |
Trigger Coupling |
DC, Noise Suppression |
Memory Depth |
50M (shared by 4 channels) Auto,10K,100K,1M,10M |
Trigger Level Range |
±10 divisions |
Sample Bit |
8 |
Display |
YT, Zoom, Roll |
Vertical Accuracy |
±3% |
Roll Mode |
200ms/div~1000s/div |
Vertical Stall |
5mV~10V |
Math |
Dual Waveform\FFT |
Vertical offset |
± 2.5V (probe X1, <500mV/div) ±120V (probe X1, ≥500mV/div) |
Automatic Setting |
Support |
Invert |
Support |
Automatic Measurement |
23 items |
Channel Coupling |
DC, AC |
Cursor |
Horizontal Cursor, Vertical Cursor, Phase Measurement |
Time Base Stall |
50ns~1ks (1ns/div~1ks/div, step by 1~2~5) |
Power Supply |
USB Port, DC Port |
Time Base Accuracy |
20ppm(typical value,ambient temperature +25℃) |
Data Transfer Method |
USB |
Add New Comment