Answer
Sep 15, 2014 - 02:39 PM
The ATS eScan uses a switch ratio calculation test to measure cat efficiency. An A/F sensor signal doesn't move enough to perform this test. On vehicles with A/F sensors you can graph the A/F sensor and rear O2 sensor PID's and perform an OSC converter test using propane.